What Is The Parallel Short-Circuit Current Of Lithium Iron Phosphate Batteries?
What Is The Parallel Short-Circuit Current Of Lithium Iron Phosphate Batteries?
The value of parallel short-circuit current of lithium iron phosphate battery depends on the rated current and number of batteries.
The formula is: parallel short-circuit current=maximum battery current×number of batteries.
For example, if a group of batteries has a maximum battery current of 10A, and five batteries are connected in parallel, the parallel short-circuit current will be 50A. Make sure that the battery protection system BMS is rated for this current to prevent overheating or burning hazards.
First, Calculation of short-circuit current of lithium iron phosphate battery parallel connection
When lithium iron phosphate batteries are connected in parallel, the calculation of short-circuit current is the key. It is directly related to the safety and stability of the BMS system. The value of the parallel short-circuit current is determined by the rated current of the battery, that is, the maximum current that can be output when the battery is working normally, and the number of batteries connected in parallel. Through a simple mathematical formula, we can quickly derive the value of parallel short-circuit current.
Taking a group of LiFePO4 batteries as an example, if the maximum current of each battery is 10A and we connect 5 such batteries in parallel, the total short-circuit current will be 50A. This is a considerable current value and must be handled with care.
Second, system safety considerations
When designing a parallel system for Li-FePO4 batteries, we not only need to calculate the short-circuit current, but also consider whether the rated current of the BMS system is large enough to accommodate this current. If the parallel short-circuit current exceeds the rated current of the BMS system, it may lead to serious consequences such as overheating, burning or even explosion of the battery.
Therefore, choosing the right battery, adopting reliable connection methods, installing temperature control devices, and reasonably controlling the charging and discharging process are all important links to ensure system safety.
Third, the factors affecting the short-circuit current
In addition to the rated current and the number of batteries, there are some other factors that will also affect the short-circuit current of lithium iron phosphate batteries. For example, the internal design structure of the battery, the choice of electrode materials and the service life of the battery will have an impact on its safety. In addition, external environmental factors such as temperature, vibration and external collision may also lead to short-circuit phenomenon inside the battery.
To summarize, when designing and using the parallel system of lithium iron phosphate batteries, we must comprehensively consider various factors to ensure the safety and stability of the BMS system. Through scientific calculation methods and rigorous safety measures, we can give full play to the advantages of lithium iron phosphate batteries to provide reliable power support for a variety of application equipment.
English
Custom 24V Lithium Battery Pricing
The price variation for custom 24V lithium batteries fundamentally stems from “base cost + functional cost + customization cost + compliance cost.”
Read MoreCustomized 48V Lithium Batteries: High Demand in Three Key Industries
Large medical carts, portable testing instruments, and other equipment require a 48V battery to provide stable power, while also complying with the ISO 13485 medical standard to avoid electromagnetic interference affecting device accuracy.
Read MoreIEC 62619 Safety Testing Standard for Energy Storage Batteries
In addition to covering traditional tests included in existing lithium battery standards, such as electrical tests, thermal tests, and mechanical tests, the new standard introduces dedicated sections to assess the Battery Management System (software evaluation).
Read More